More actions
Emerson SP2403 not turning on repair | |
---|---|
Device | Emerson SP2403 |
Affects part(s) | D18 diode (PR 1600) |
Needs equipment | multimeter, soldering iron, soldering station. |
Difficulty | ◉◉◉◌ Hard |
Type | Soldering |
This article is a stub. You can help Repair Wiki grow by expanding it
Problem description
Diagnosing and fixing an issue with an Emerson SP2403 inverter that does not turn on or react to power when connected to 3 phase 400V AC
Symptoms
- Not turning on.
- Not reacting to power.
- MOSFET gate switching for split second then stopping and repeating when measured with an oscilloscope.
- VCC for UC2844B going up to 16V then dropping to 7V and raising again on a loop.
Solution
Measure D18 diode in with a multimeter in diode mode. Make sure it measures 0.4-0.7V, anything less or more and it's dead. In this case it was 0.1V on both ways which indicates that it's dead. The original diode was a PR1600. A photoflash rectifier diode with 1600v reverse voltage. I've replaced it with a rectifying diode with 1kV reverse voltage and it started switching properly again and working.If the issue has a single, specific solution, provide it in this section and delete the sub-headers below. Otherwise, if there are multiple potential causes for the problem, outline the process of identifying the root cause and offer corresponding solutions below.