APC Back-UPS ES 350VA: Difference between revisions

From Repair Wiki
(Created Page)
 
No edit summary
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
{{Device page
|Manufacturer=APC
|Device type=Other
}}
{{stub}}
{{stub}}
{{Device page
 
|Manufacturer=APC}}


==Guides==
==Guides==
Line 29: Line 32:


==Reference measurements (also schematics if available)==
==Reference measurements (also schematics if available)==
Internal Fuse - 40 Amp Blade Style<gallery showthumbnails="1">
Internal Fuse - 40 Amp Blade Style
 
Battery - RBC35<gallery showthumbnails="1">
</gallery>
</gallery>



Latest revision as of 20:44, 17 April 2024

APC Back-UPS ES 350VA
Manufacturer APC
Code name
Release date
Device type Other


This article is a stub. You can help Repair Wiki grow by expanding it


Guides

Explanatory Guides

Repair Guides

40 AMP FUSE REPLACEMENT

The board has a 40-amp blade-style fuse that may go bad. If the device has a known good battery and the device is having the symptoms of "Replace Battery" per the user guide. To replace the fuse:

  • Remove battery and battery cover
  • Remove the 4 Phillips screws
  • Remove back cover
  • Disconnect all connectors on main board and remove.
  • Desolder and resolder a new 40-amp blade-style fuse.
  • Place the main board back and reconnect all connectors.
  • Feed battery wires back through labeled openings on back cover and reinstall.
  • Screw in 4 screws.
  • Install battery and cover.
  • Complete.

Device pictures

PCB pictures

Reference measurements (also schematics if available)

Internal Fuse - 40 Amp Blade Style

Battery - RBC35

More Information/External Sources

Product Page: https://www.apc.com/us/en/product/BE350G/apc-backups-es-350va-120v/

User Guide: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EALN-7CEQDH_R1_EN.pdf&p_Doc_Ref=SPD_EALN-7CEQDH_EN