More actions
APC Back-UPS ES 350VA | |
---|---|
Manufacturer | APC |
Code name | |
Release date | |
Device type | Other |
This article is a stub. You can help Repair Wiki grow by expanding it
Guides
Explanatory Guides
Repair Guides
Create a Guide
40 AMP FUSE REPLACEMENT
The board has a 40-amp blade-style fuse that may go bad. If the device has a known good battery and the device is having the symptoms of "Replace Battery" per the user guide. To replace the fuse:
- Remove battery and battery cover
- Remove the 4 Phillips screws
- Remove back cover
- Disconnect all connectors on main board and remove.
- Desolder and resolder a new 40-amp blade-style fuse.
- Place the main board back and reconnect all connectors.
- Feed battery wires back through labeled openings on back cover and reinstall.
- Screw in 4 screws.
- Install battery and cover.
- Complete.
Device pictures
Please consider contributing pictures to this section!
PCB pictures
Please consider contributing pictures to this section!
Reference measurements (also schematics if available)
Internal Fuse - 40 Amp Blade Style
Battery - RBC35Please consider contributing pictures to this section!
More Information/External Sources
Product Page: https://www.apc.com/us/en/product/BE350G/apc-backups-es-350va-120v/